Earth Posts~

90% of Electric Fence problems are caused by poor grounding

~~~1773~1813~~
Earthing Table~

The majority of problems with Electric Fences are associated with poor contact between the earth rod and the ground.

A chemical reaction is always present between metal and the ground resulting in oxidisation (rusting) of the metal. This rust is a poor conductor of electricity and will reduce the effectiveness of your electric fence. Larger energizers will require more than one earth stake that, if possible, should be located in a permanently wet patch of soil.

Do not connect to a homestead earth or position an earth within 3 meters of one.

~~~1773~1815~~
Earth Post~
A good earth stake is vital to an effective Electric Fence. This single item is 50% of the fence.
Choice of two, please use the drop-down box to select your choice.~
There is always going to be a chemical reaction taking place between metal and soil. The greater the surface area between the earthstake and the ground the better.~Short Post|80054 & 90150C|Long Posts|14041|1.5m|15017|~1773~1816~earth post.~
Lightning Diverter~Protects the energizer from lightning strikes on the fence line. Very important where mains units are sited within fire-risk buildings, barns, hay sheds. Likely to be a legal requirement in the future.~Protects the energizer from lightning strikes and power surges. Install a lightning diverter ( commonly referred to as a lightning arrestor) between the fence and the Energizer. This will divert the electricity from lightning strikes on the fence, to the earth before it damages the energizer or the main electrical circuit. Lightning diverters do not arrest or stop the flow of current from a lightning strike, they direct the flow of current into the earth when properly installed.
NEVER connect the fence's earth system to the domestic protective earth system.~Lightning Diverter|14085C|~1773~1817~lightning arrestor,lightning protection, lightning, lightning diverter~
High Voltage Cable~Used to connect multiple earth stakes or connect fences by running beneath a gate or other open ground. Connect internally housed mains units to the fence.~Used to connect multiple earth stakes or connect fences by running beneath a gate or other open ground. Connect internally housed mains units to the fence.
~10m Reel|15321|25m Reel|14040|50m Reel|15525|100m Reel|15956|~1773~2280~insulated cable, underground cable~
Electrifiable Box~Protect your vulnerable energiser, the whole box is electrified to zap the thief.~Best protection against your vulnerable energiser being stolen, may be locked and electrified. The entire box is electrified and insulated from the integrated earth post. Supplied with earth stake and 2 plastic keys. Will fit most energizers. Supplied with earth stake and 2 plastic keys.
Internal Dimensions 330 x 380 x 280mm~Electrifiable Box|15444|~1773~1818~electrifiable box~